Delayed Egress Electromagnetic Lock
The Delayed Egress Electromagnetic Lock is an All-in-One delayed egress lock with a built-in sensor that detects pressure applied to outward swinging doors. Built-in sounder, voice and CCTV monitoring combinations make this ideal for applications requiring Loss Prevention, Life Safety and Traffic Control. The DE8310 is unique in that there is no need to replace existing door hardware making this an easy and affordable delayed egress solution.
STANDARD FEATURES
- All-in-One delayed egress lock
- Built in "sensor" detects when pressure is applied to outward swinging doors - No need to replace existing door hardware
- Field selectable 15 or 30 second release delay with field selectable 0 to 3 second nuisance delay
- Provision for IBC, SBC, NFPA101, UBC, BOCA or NBC of Canada compliance
- Unique highly visible "Red/Green" light panel indicates status of door (local)
- Available with built-in sounder, voice and CCTV monitoring combinations
- Camera comes with BNC and RCA video outputs
- Includes 960 Keyswitch for reset and override, 15 second Building Code Sign; base unit includes external sounder
- Built-in Security Condition Sensor (SCS) feature indicates that the door is closed and bonded
- Dry contact SPDT and DPDT relays provided for local and/or remote monitoring
- Auto sensing voltage from 12 to 24 VDC
- Up to 1200lbs (540kg) holding force
PLUS! Standard MultiMag® features included
- Adjustable keyhole mounting
- Convenient plug-in wiring terminals
- Easy access wiring cavity
- Encapsulated 4-bolt 'Drop-Stop" mounting
- Self-drilling tek™ fasteners
WARRANTY
5 Year Warranty on electromagnetic lock.
1 Year Warranty on camera and built-in voice/sounder components
Armature Plate Requirements:
5/8"D x 2-3/8"H x 7-7/16"L (16mm x 60mm x 189mm)
Auto Sensing Voltage:
12VDC to 24VDC
Power Consumption:
With Camera: 12VDC - Max 0.79A / 24VDC - Max 0.39A
With Voice/or Sound: 12VDC - Max 0.66A / 24VDC - Max 0.33A
Base Unit*: 12VDC - Max 0.61A / 24VDC - Max 0.32A
* Ratings shown include the external sounder required by NFPA101
Local Alarm Output:
SPDT 1.0A 120VAC, 2A 30VDC
Remote Alarm Output:
DPDT: 1.0A 120VAC, 2A 30VDC
NOTE: RCI recommends our filtered, regulated DC voltage 10 Series power supplies.
Certification:
- cULus Listed GWXT Auxiliary locks | patent pending
- cURus Component for use in FWAX Special Locking Arrangements
Holding Force:
Up to 1200 lbs (540kg) pounds
Operating Temperature:
Circuit board operating temperature: 14° to 140°F (-10° to 60°C)